Tritex - Your Marine Partner in Asia
Singapore (Tritex HQ) China USA Hong Kong Taiwan Maldives Thailand Indonesia Myanmar
Products Overview
Sort Products by Manufacturer Overview
A/Sea
BEP Marine
Catef Marine Fire
Condaria
Coleman
Cruisair
Cummins MerCrusierDiesel
Cummins Onan
Dometic
Grunert
Hella Marine
IVG
Kraus and Naimer
Marine Air
Racor
Reverso
Reya
Sealand (Dometic)
Sea Recovery
ShurFlo
TriPower
Tundra
Twin Disc
Vetus
Vimar
Xantrex
ZF
Home: Products Overview: Sort Products by Manufacturer: Condaria
Condaria
Condaria Logo

Condaria was born and has developed in the very special field of middle capacity air-conditioning systems for leisure yachts and custom boats.
The particular technology, and the acquired "know-how" in over thirty years of presence at this market, led Condaria to develop a line of system components specially designed for using on marine units.

WATER CHILLER / HEAT PUMP UNITS (PCWM/FCL)

PCWM/FCL units are used to chill the water that is circulated to the spaces to be cooled as a heat-transfer medium. In winter, the reverse cycle heat pump warms the circulated water, providing efficient heating to the spaces. PCWM/FCL units are normally installed in the engine compartment, and are associated to the air handling units (fan-coil type), located in the spaces to be air-conditioned.

Marine grade materials are used, i.e. stainless steel and cupro-nickel; the most advanced control technology is applied, as well as proper devices to reduce noise and vibration.


PCWM/FCL (1 compressor)
PCWM/FCL (2 compressors)
PCWM/FCL (3 compressors)
PCWM/FCL (4 compressors)
PCWM/FCL (1 compressor)
PCWM/FDL 6001 (1 compressor)
Model45016001750190011200115001
Part number410000107410000507410001307410001807410002907410003907
Rated cooling capacitykCal/h4.5006.0007.5009.00012.00015.000
Btu/h18.00024.00030.00036.00048.00060.000
Watt5.2326.9768.72010.46513.95317.441
Rated heating capacitykCal/h5.6257.5009.37511.25015.00018.750
Btu/h22.50030.00037.50045.00060.00075.000
Watt6.5408.72010.90013.95317.44121.800
CompressorsQty x tons1 x 1,51 x 21 x 2,51 x 31 x 41 x 5
Ampere220/1/5012,9015,4017,9019,20N/AN/A
220/3/5013,1015,0015,4017,1220,00N/A
380/3/50NA5,557,457,9610,0011,70
kW max.1,803,003,253,505,005,50
Dimension in mmRemote ECP
l x d x h
NANANANANANA
Dimension in mmUnit-fitted ECP
l x d x h
660 x 450 x 400660 x 450 x 400750 x 450 x 400800 x 500 x 5001.000 x 500 x 5001.000 x 500 x 500
Weight
kg
659595100125130


PCWM/FCL (2 compressors)
PCWM/FDL 18002 (2 compressors)
Model90021200215002180022400230002
Part number410002507410003507410004507410005207410007407410008507
Rated cooling capacitykCal/h9.00012.00015.00018.00024.00030.000
Btu/h36.00048.00060.00072.00096.000120.000
Watt10.46513.95317.44120.93027.90734.883
Rated heating capacitykCal/h11.25015.00018.75022.50030.00037.500
Btu/h45.00060.00075.00090.000120.000150.000
Watt13.08017.44121.80026.16034.88343.600
CompressorsQty x tons2 x 1,52 x 22 x 2,52 x 32 x 42 x 5
Ampere220/1/5020,4028,8030,3034,80N/AN/A
220/3/50N/A20,0024,8028,0030,6033,00
380/3/50N/A10,7512,3613,8018,7021,50
kW max.4,205,206,006,809,5010,50
Dimension in mmRemote ECP
l x d x h
800 x 500 x 4501.000 x 500 x 5001.000 x 500 x 5001.050 x 550 x 5501.050 x 600 x 5501.050 x 600 x 550
Dimension in mmUnit-fitted ECP
l x d x h
1.000 x 500 x 5001.000 x 500 x 5001.000 x 500 x 5001.050 x 550 x 550N/AN/A
Weight
kg
135150160190220245


PCWM/FCL (3 compressors)
PCWM/FDL 22503 (3 compressors)
Model1800322503270033600345003
Part number410006007410006807410008107410010308410011507
Rated cooling capacitykCal/h18.00022.50027.00036.00045.000
Btu/h72.00090.000108.000144.000180.000
Watt20.93026.16031.39541.86052.325
Rated heating capacitykCal/h22.50028.12533.75045.00056.250
Btu/h90.000112.500135.000180.000225.000
Watt26.16032.70339.24452.32565.406
CompressorsQty x tons3 x 23 x 2,53 x 33 x 43 x 5
Ampere220/1/5020,4028,8030,3034,80N/A
220/3/50N/A20,0024,8028,0030,60
380/3/50N/A10,7512,3613,8018,70
kW max.4,205,206,006,809,50
Dimension in mmRemote ECP
l x d x h
800 x 500 x 4501.000 x 500 x 5001.000 x 500 x 5001.050 x 550 x 5501.050 x 600 x 550
Dimension in mmUnit-fitted ECP
l x d x h
1.000 x 500 x 5001.000 x 500 x 5001.000 x 500 x 5001.050 x 550 x 550N/A
Weight
kg
220230260350370


PCWM/FCL (4 compressors)
PCWM/FDL (4 compressors)
Model300043600440004480046000472004
Part number410009807410011107420000045410011600420011608420000072
Rated cooling capacitykCal/h30.00036.00040.00048.00060.00072.000
Btu/h120.000144.000160.000192.000240.000288.000
Watt34.88341.86046.51055.81469.76783.720
Rated heating capacitykCal/h37.50045.000N/A60.00075.000N/A
Btu/h150.000180.000N/A240.000300.000N/A
Watt43.60052.325N/A69.76787.209N/A
CompressorsQty x tons4 x 2,54 x 34 x 3,34 x 44 x 54 x 6
Ampere220/1/5062,8066,8072,00N/AN/AN/A
220/3/5043,0055,0057,6062,0072,0085,00
380/3/5020,6023,4024,0025,8040,0052,30
kW max.11,5012,0015,0018,0023,0027,00
Dimension in mmRemote ECP
l x d x h
1.200 x 700 x 5501.200 x 700 x 5501.050 x 600 x 6001.500 x 830 x 6001.500 x 830 x 6001.250 x 730 x 600
Dimension in mmUnit-fitted ECP
l x d x h
N/AN/AN/AN/AN/AN/A
Weight
kg
300315375420450475


PCWM/FCL - Custom vertical version (on request)
PCWM/FDL Custom
Model1800218003225033000436004
Part number410005211410006011410006808410009808410010401
Rated cooling capacitykCal/h18.00018.00022.50030.00036.000
Btu/h72.00072.00090.000120.000144.000
Watt20.93020.93026.16034.88341.860
Rated heating capacitykCal/h22.50022.50028.12537.50045.000
Btu/h90.0090.000112.500150.000180.000
Watt26.16026.16032.70343.60052.325
CompressorsQty x tons2 x 33 x 23 x 2,54 x 2,54 x 3
Ampere220/1/5034,8036,8042,8062,8066,80
220/3/5028,0029,5034,5043,0055,00
380/3/5013,8013,8014,9020,6023,40
kW max.6,807,608,9011,5012.00
Dimension in mmRemote ECP
l x d x h
1.100 x 400 x 9501.100 x 400 x 9501.100 x 400 x 9501.100 x 460 x 1.0001.100 x 460 x 1.000
Dimension in mmUnit-fitted ECP
l x d x h
N/AN/AN/AN/AN/A
Weight
kg
190220230300315


For RFQ (Request For Quotation), kindly drop us an email, and we will respond to your email within 1 working day.
Enquiries: mgt@tripower.com.sg
Back to top
A/SeaBEP MarineColemanCruisairCumminsOnanDometicGrunertHyundai MarineKraus and NaimerMarine AirRacor
ReversoReyaDometic SealandSea RecoveryShurfloTundraTwinDiscVetusVimarXantrexZF Group
Home About Us Products Market Place Contact Us Privacy Policy Sitemap


© 2007 Tritex Group All Rights Reserved No. 3 Tuas Avenue 18A. Singapore 638852 Tel: 65-68611188 Fax: 65-68614263